Applications / Production
End-of-line test with the instruments on your bench.
An operator scans a serial number. The station powers the unit, measures it, shows PASS or FAIL across the room and prints the label. The engineer writes that sequence once, against the same instruments they use in the lab: in Python while developing it, in JavaScript when the station runs it on its own.
| Operator sees | One dashboard, nothing else |
|---|---|
| Sign-in | PIN per person; locks after 5 wrong PINs |
| Network | Closed by default; remote access is opt-in |
| Input | Barcode scanner, serial or keyboard mode |
| Instruments | SCPI over LAN, USB-TMC or serial |
| Output | PASS/FAIL banner, log, label with serial |
| Plan | PRO+ |
What is on it, and how Muxit reaches each part.

- 1Touchscreen on the station PC, showing the operator dashboard in a local browser.operator mode
- 2Fixture with pogo pins, wired to the instruments. Muxit doesn't need to know about it.—
- 3Barcode scanner. In serial mode every scan is an event for the script; in keyboard mode it types into an Input widget.LineText · Input
- 4Label printer through its normal OS driver. Templates with barcodes, QR codes and a serial counter.LabelPrinter
- 5Programmable DC supply. Voltage, current limit, output, measured current.Scpi
- 6Programmable electronic load. Constant current, input on and off.Scpi
- 76½-digit bench DMM. The measurement that decides pass or fail.Scpi
One screen, readable from across the room.


| Widget | Does |
|---|---|
| status-banner | Fills its area with one colour and one word; the text scales with the widget |
| steps | The stages of the test, with running, pass and fail icons |
| progress | A determinate bar, or a sweep when the length is unknown |
| input | Type or scan into a property; selects all on focus, commits on Enter |
| select | Pick the product variant; segmented buttons sized for gloved fingers |
| terminal | The process log, coloured by severity, with filter, scroll lock and save |
When the script needs a decision it asks with ask.confirm, ask.choose or ask.text; on an operator station those appear as a dialog on the dashboard.
The test is a script you can read.
// eol-test.js: one unit per scan. Runs until Stop.
const station = connector("station"); // state for the dashboard
const psu = connector("psu"); // programmable supply
const load = connector("load"); // electronic load
const dmm = connector("dmm"); // bench DMM
const labels = connector("labels"); // label printer
while (true) {
station.status = "WAITING";
const serial = waitFor("connector:scanner.scan");
station.reset();
station.serial = serial;
station.status = "RUNNING";
psu.current_limit = 0.5;
psu.voltage = 12;
psu.output = true;
delay(300);
station.setStep(0, "running");
const idle = psu.measured_current;
const idleOk = idle < 0.08;
station.setStep(0, idleOk ? "pass" : "fail");
station.setStep(1, "running");
load.current = 1.0;
load.input = true;
delay(500);
const vout = dmm.voltage;
const loadOk = vout > 4.9 && vout < 5.1;
load.input = false;
station.setStep(1, loadOk ? "pass" : "fail");
psu.output = false;
const pass = idleOk && loadOk;
station.status = pass ? "PASS" : "FAIL";
log.info(`${serial} ${station.status} vout=${vout}`);
if (pass) labels.print({ serial, vout: vout.toFixed(3) });
}# eol_test.py: one unit per scan. Runs until Ctrl+C.
import time
import muxit
m = muxit.connect()
station = m.connector("station") # state for the dashboard
psu = m.connector("psu") # programmable supply
load = m.connector("load") # electronic load
dmm = m.connector("dmm") # bench DMM
labels = m.connector("labels") # label printer
while True:
station.status = "WAITING"
serial = m.events.wait("connector:scanner.scan")
station.reset()
station.serial = serial
station.status = "RUNNING"
psu.current_limit = 0.5
psu.voltage = 12
psu.output = True
time.sleep(0.3)
station.setStep(0, "running")
idle = psu.measured_current
idle_ok = idle < 0.08
station.setStep(0, "pass" if idle_ok else "fail")
station.setStep(1, "running")
load.current = 1.0
load.input = True
time.sleep(0.5)
vout = dmm.voltage
load_ok = 4.9 < vout < 5.1
load.input = False
station.setStep(1, "pass" if load_ok else "fail")
psu.output = False
result = "PASS" if idle_ok and load_ok else "FAIL"
station.status = result
print(f"{serial} {result} vout={vout}")
if result == "PASS":
labels.print({"serial": serial, "vout": f"{vout:.3f}"})What happens
- waitFor blocks until the scanner reads a label. Scans that arrive while a unit is still under test are kept for the next round.
- The supply comes up with a current limit; the idle current is the first check.
- The load draws 1 A and the bench DMM reads the output: the second check.
- The banner shows the result; a passing unit gets a label with its serial and measured voltage.
station is a Virtual connector like the example's fixture-line: it holds the status, steps and serial that the dashboard shows. Instrument property names come from each connector's SCPI schema. Stop ends a script at once, so put safe states before the loop and hard limits in the connector.
Label templates are designed under Tools › Label Printing, with fields and a live preview. Printing to a real printer is Pro; previews work on every plan.
The Python tab is the same test, for while you develop it at your desk; the dashboard shows every step either way. The station itself runs the JavaScript version: a script inside Muxit is what an operator can start from the station's screen, and it keeps running when your laptop closes.

Who can reach the station, who can change the test, and what gets recorded.
| Role | Can |
|---|---|
| Operator | Sign in with a PIN, use the operator dashboards, start scripts from scripts/operator/, answer prompts, press Stop |
| Engineer | Everything in the full interface: scripts, connectors, dashboards |
| Admin | An engineer who also manages accounts and the sign-in policy |
Enforced by the server
Under the Dashboards only policy the server refuses edits to scripts, connectors, dashboards and settings, driver installs and safety-level changes from anyone not signed in as engineer or admin. It's more than a hidden menu.
Recorded LAB
Safety policies per connector set limits and confirm gates. The audit log records every blocked, simulated or confirmed operation and every safety-level change, one JSON line each, naming the script or the signed-in person.
On the network
| Situation | What happens |
|---|---|
| Out of the box | Muxit listens on the station PC only. Nothing else on the network can reach it, and it doesn't announce itself on the LAN. |
| Remote access on | An admin turns it on and sets a password. Other computers get a login page; until a password is set, every request from them is refused. HTTPS with a self-signed certificate is optional. |
| From outside the site | Not directly: through a VPN such as Tailscale. Muxit does not relay connections through a server of ours. |
| An engineer at their desk | Signs in with their own account and gets the full interface for that connection only. The station stays locked for the operator. |
Want a picture of every unit as well? See visual inspection and image records.
Instruments and plan.
| Part | How Muxit reaches it |
|---|---|
| Programmable DC supply | Scpi · LAN / USB-TMC / serial |
| Programmable electronic load | Scpi · LAN / serial |
| 6½-digit bench DMM | Scpi · LAN / RS-232 |
| Barcode scanner | LineText (serial mode) or Input widget (keyboard mode) |
| Label printer (Brother, Zebra, Epson) | LabelPrinter, through the OS printer driver |
| Touchscreen on the station PC | Operator mode, in a local browser |
A whole station uses more than the three connectors on Free, and operator mode, accounts and label printing are Pro. Lab adds the audit log and per-connector safety policies. One installation per station. Pricing →
Every instrument here needs a remote interface (LAN, USB-TMC or serial). Handheld meters and supplies with only knobs can't take part in an automated test.
What it doesn't do (yet).
- No MES integration out of the box. A script can call a webhook or write a file per unit.
- No certification such as 21 CFR Part 11.
- The audit log is per installation; there is no central log across stations, and it doesn't yet record every allowed write.
- GPIB-only instruments need a Prologix or AR488 adapter; GPIB support is so far tested against simulated adapters only.
Try it on Free, run it on Pro.
Every new workspace has the Production Line example. On Free you can connect three instruments and preview labels. A full station needs Pro, which also brings operator mode.
Related applications
Visual inspection and image recordsA camera picture next to every measurement, and an AI check of what the picture shows.
Programming and calibration fixturesPower up with a current limit, flash with the vendor tool, trim, verify, log the unit.
R&D characterisationSweeps, I/V curves and corner cases, logged to CSV and repeatable next week.
Power electronicsEfficiency and regulation of LED drivers, DC-DC converters and power supplies over load.